| Type of building | example of application | Suggested fire rating or smoke control class | Description (symbol of doors compliant with the requirements) |
| residential buildings (without fire lobby) | entrance doors for flats located in the buildings more than 25 m high (from the the 9th floor up) | EI 30 EI 30/S 60 (Sa, Sm) | KWARC (DT-K32/M) GRANIT typ 2 (DT-PW/II) |
| hotels, boarding houses | entrance doors for flats located in the buildings more than 12 m high (from the 4th floor up) | EI 30 EI 30/S 60 (Sa, Sm) | 42 dB (DT-AW/M, DT-AW/D) EI 30 (DT-K32/M, DT-PP-DY) |
| residential buildings | doors separating fire areas (buildings without fire lobbies) | EI 30 (wys. do 12 m) EI 60 (wys. pow. 12 m) | EI 30 (DT-K32/M) EI 60 (DT-PP60) |
| hotels, boarding houses, public buildings | EI 60 (wysokość budynku do 55 m) | EI 60 (DT-PP60) | |
| special applications | boiler room doors | EI 60 | EI 60 (DT-PP60) |
| garage doors (single-family housing excluded) | EI 30 (wejście z przedsionka ppoż) EI 60 | EI 30 (DT-K32/M) EI 60 (DT-PP60) |
| Type of building | example of application | Acoustic requirements | Recommended by Porta | Description (symbol of doors compliant with the requirements) |
| Blocks of flats | Flat entrances in the buildings | > Rw 27 dB | Rw 32 dB | AGAT, OPAL, KWARC (DT-K32/M) GRANIT typ 1 i 2 (DT-PW/II) |
| Higher class hotels | directly from the vestibule to the rooms | Acc. to the design | Rw 32 dB Rw 42 dB | 42 dB (DT-AW/M,DT-AW/PS, DT-AW/D) 32 dB (DT-A32/M, DT-A32/PS) EI 30 (DT-K32/M, DT-PP-DY) |
| From the vestibule to internal vestibule, lobby | > Rw 32 dB | Rw 32 dB | 32 dB (DT-A32/M, DT-A32/PS) EI 30 (DT-K32/M, DT-PP-DY) | |
| Lower class hotels, Holiday centres | directly from the vestibule to the rooms | > Rw 32 dB | Rw 32 dB | 32 dB (DT-A32/M, DT-A32/PS) EI 30 (DT-K32/M, DT-PP-DY) |
| From the vestibule to internal vestibule, lobby | > Rw 27 dB | Rw 27 dB | 27 dB (DT-A27/M, DT-A27/PS) | |
| hotels, Holiday centres | TV, club, conference rooms | Acc. to the design | Rw 42 dB | 42 dB (DT-AW/M, DT-AW/PS, DT-AW/D) |
| halls of residence, boarding houses, boarding homes for aged, sanatoria | directly from the vestibule to the rooms | > Rw 32 dB | Rw 32 dB | AGAT, KWARC (Metal door frame) 32 dB (DT-A32/M) (Metal door frame) EI 30 (DT-K32/M) (Metal door frame) |
| From the vestibule to internal vestibule, lobby | > Rw 27 dB | Rw 27 dB | 27 dB (DT-A27/M) (Metal door frame) | |
| TV rooms, reading rooms | Acc. to the design | Rw 42 dB | 42 dB (DT-AW/M) (Metal door frame) | |
| Hospitals | Doctor's surgeries | Acc. to the design | Rw 42 dB | 42 dB (DT-AW/M) (Metal door frame) |
| Doctors' and nurses' rooms | Acc. to the design | Rw 27 dB | 27 dB (DT-A27/M) (Metal door frame) | |
| Administration and office buildings | Work rooms | > Rw 22 dB | Rw 27 dB | 27 dB (DT-A27/M, DT-A27/PS) |
| Rooms for concentrated work | > Rw 27 dB | Rw 32 dB | 32 dB (DT-A32/M, DT-A32/PS) EI 30 (DT-K32/M, DT-PP-DY) | |
| Director's offices | > Rw 27 dB | Rw 42 dB | 42 dB (DT-AW/M, DT-AW/PS, DT-AW/D) |
| Type of building | example of application | Suggested burglar-proof class | Description (symbol of doors compliant with the requirements) |
| residential buildings | Flat entrance doors | klasa B klasa C | OPAL GRANIT typ 1 i 2 (DT-PW/II) |
| Type of building | example of application | Required heat transfer coefficient | Coefficient determined for Porta doors | Description (symbol of doors compliant with the requirements) |
| Single-family houses | Building entrance doors | U≤2,6 W/(m2K) | U=2,11 W/(m2K) | GDAŃSK, TORUŃ, SZCZECIN |
| Single-family housing and flat blocks, public buildings with low and medium traffic | Building entrance doors | U≤2,6 W/(m2K) | U=1,5 W/(m2K) (Glazed doors) U=1,6 W/(m2K) (Doors without glazings) | GDYNIA, WROCŁAW (DZ-F) |